Process external heating of pre-filters for applications with high dust concentrations combined with high process temperatures (above maximum temperature of pre-filter)
Combinable with gas sampling probes JES-301 and JES-301L
Benefits
Sampling without influence on the sample gas
No corrosion due to condensate formation
Uniform reliable heating of the pre-filters independant of the operating conditions
Cleaning via back purge connection
Easy mounting
Safe operation
Features
Corrosion resistant stainless steel pipe
Fully electronic temperature controller with low temperature alarm and excess temperature switch-off
Error message for sensor short-circuit and broken sensor
Mounting directly at the standard process and gas sampling probe flange
Pipe length 400 mm
Temperature adjustment range 5 °C…200 °C, optionally 5 °C..320 °C
Sampling pipes of arbitrary length can be screwed in on process side